Interconnect bay

Single-density half-height server blade

Double-density half-height server blade (Server A)

Double-density half-height server blade (Server B)

Single-density full-height server blade

1

NIC 1 (embedded)

NIC 1 (embedded)

NIC 3 (embedded)

NIC 1 (embedded)

2

NIC 2 (embedded)

NIC 1 (embedded)

NIC 4 (embedded)

NIC 2 (embedded)

3

Mezzanine slot 1, port 1

NIC 2 (embedded)

Mezzanine slot 1, port 1

4

Mezzanine slot 1, port 1

NIC 2 (embedded)

Mezzanine slot 1, port 1

5

Mezzanine slot 2, port 1

Mezzanine port 1

Mezzanine slot 2, port 1

Mezzanine slot 3, port 2

6

Mezzanine slot 2, port 1

Mezzanine port 1

Mezzanine slot 2, port 1

Mezzanine slot 3, port 2

7

Mezzanine slot 2, port 2

Mezzanine port 1

Mezzanine slot 2, port 2

Mezzanine slot 3, port 1

8

Mezzanine slot 2, port 2

Mezzanine port 1

Mezzanine slot 2, port 2

Mezzanine slot 3, port 1

For more information on mapping to interconnect ports, see the HP BladeSystem c7000 Enclosure Setup and Installation Guide on the HP website.